  • In accordance with IEC 60529 (Note).
  • Shock resistance: Tested using a drop-type shock testing machine. Tests are conducted along the axial direction of the main spool and the moving armature, as well as in the direction perpendicular to the axis, under both energized and de-energized conditions. No malfunction occurs in any of these cases (values ​​represent initial specifications).
  • Vibration resistance: Tested across a frequency range of 45–2000 Hz along the axial direction of the main spool and the moving armature, as well as in the direction perpendicular to the axis, under both energized and de-energized conditions. No malfunction occurs in any of these cases (values ​​represent initial specifications).

Поделитесь с друзьями:

SY Series Pneumatic Solenoid Valve Order Code Generator

Код текущего заказа:
SY3120-5LZD-M5
SY
2
3
3
1
4
20
5
–
6
–
7
5
8
L
9
Z
10
D
11
M5
12
–
13
–
14
–
15
–














Примечания:
1. Series: 3=3000, 5=5000, 7=7000, 9=9000. Function: 1=2-pos single, 2=2-pos double, 3=3-pos closed, 4=3-pos exhaust, 5=3-pos pressure.
2. Port type: 20=direct piping, 40=base mounting. External pilot R only when port type=40.
3. Coil T (power-saving) only valid for DC24V/DC12V. Voltage: 5=DC24V, 6=DC12V, 1=AC100V, 2=AC200V, 3=AC110/115V, 4=AC220/230V.
4. Port by series: 3000 = M5/C4/C6/N3/N7; 5000 = 01/C4/C6/C8/N3/N7/N9; 7000 = 02/C8/C10/N9; 9000 = 03/04/C10/C12/N9/N11.
5. Thread: blank=RC, F=G, N=NPT. Bracket F1 foot-mount only for 2-pos single; series 9000 rejects bracket.
6. Custom X20=direct piping external pilot, X90=FKM seal. CE: Q = CE compliant.
For non-standard options, please confirm before ordering.


SeriesSY3000SY5000SY7000SY9000
ЖидкостьВоздух
Internal Pilot Pressure Range2-position single solenoid0,15–0,7 МПа
2-position double solenoid0,1–0,7 МПа
3-position0.2~0.7 MPa
External Pilot Supply Pressure-100 kPa~0.7 MPa
External Pilot Operating Pressure2-position single solenoid0,25–0,7 МПа
2-position double solenoid
3-position
Температура окружающей среды и жидкости-10~50°C (no freezing)
Максимальная рабочая частота2-position single / double solenoid10 Hz5 Hz5 Hz5 Hz
3-position3 Hz3 Hz3 Hz
Manual OperationNon-locking push button, screwdriver-operated turn-lock, manual push turn-lock
Pilot Valve ExhaustInternal pilotMain valve and pilot valve exhaust together
External pilotPilot valve exhaust separately
СмазкаНе требуется
MountingFree
Shock / Vibration Resistance m/s²150 / 30
Protection ConstructionDust-proof (*DIN plug / M8 connector type: IP65)
Coil Rated VoltageDC24 V, 12 V
AC 50/60 Hz100 V, 110 V, 200 V, 220 V
Allowable Voltage Fluctuation±10% of rated voltage
Потребляемая мощность24 В постоянного тока1 W {LED: 1.05 (DIN plug with LED: 1.1)}
12 В постоянного тока0.65 W {LED: 0.7 (DIN plug with LED: 0.75)}
110 В переменного тока0.9 VA (with LED: 0.95 VA)
220 В переменного тока2 VA (with LED: 2.05), 1.95 VA (with LED: 2.1)
Surge Suppression CircuitDiode (DIN plug / non-polar type: varistor)
Indicator LightLED (DIN plug AC type: Neon lamp)
Примечания:
1. *AC110V and 115V, AC220V and 230V are shared.
2. *AC115V, AC230V: allowable voltage fluctuation is -15%~+5% of rated voltage.
3. *S, Z and T types (with economizer circuit): internal circuit has voltage drop, allowable voltage fluctuation as below.
S, Z: DC24V: -7%~+10%; DC12V: -4%~+10%. T: DC24V: -8%~+10%; DC12V: -6%~+10%.


Логотип MYFEQD NEW2