| 3A / 4A Series Air Pilot Valve | ||
|---|---|---|
| Working Medium | Air (filtered through 40μm mesh or above) | |
| Actuation Type | External Air Pilot | |
| Port Thread | M5, PT1/8, PT1/4, PT3/8, PT1/2 | |
| Effective Area (Cv) | 3A110, 3A120: 10.2 mm² (Cv=0.6) | |
| 3A210, 3A220: 17 mm² (Cv=1.0) | ||
| 3A310, 3A320: 28 mm² (Cv=1.65) | ||
| 3A410, 3A420: 50 mm² (Cv=2.79) | ||
| 4A110, 4A120: 10.2 mm² (Cv=0.6), 4A130: 8.6 mm² (Cv=0.51) | ||
| 4A210, 4A220: 17 mm² (Cv=1.0), 4A230: 13.6 mm² (Cv=0.8) | ||
| 4A310, 4A320: 28 mm² (Cv=1.65), 4A330: 21.3 mm² (Cv=1.25) | ||
| 4A410, 4A420: 48 mm² (Cv=2.82), 4A430: 40 mm² (Cv=2.35) | ||
| Position Number | 4A Series | 2/2-way for single/double pilot; 5/3-way for double pilot 3-position |
| 3A Series | 3 Port 2 Position | |
| Lubrication | Not required (ISO VG32 or equivalent if needed) | |
| Operating Pressure Range | 0.15~0.8 MPa | |
| Proof Pressure | 1.2 MPa | |
| Working Temperature | -20°C ~ +70°C | |
| Body Material | Aluminum Alloy | |
| Port Thread Type | PT, NPT, G | |
| Max Operating Frequency | 5 Hz (single/double pilot 2-pos); 3 Hz (double pilot 3-pos) | |