| AD402 Series Automatic Drain Specification | |
|---|---|
| Model | AD402 series automatic drain filter |
| Working Medium | Air (filtered through 40μm mesh or above) |
| Proof Pressure | 1.0 MPa |
| Operating Pressure Range | 0.15~0.85 MPa |
| Port Thread | G1/2 |
| Working Temperature | -5~60°C (No Freezing) |
| Drain Port Thread | G3/8 |
| Recommended Oil | Turbine Oil No.1 (ISO VG32) |
| Body Material | Die-cast Aluminum with Corrosion-resistant Paint |
|
Note: 1. When installing the drain pipe, use a tube with inner diameter ≥10mm, length ≤5m, and do not bend upward. 2. Compressor power must be ≥3.7kW, 400 L/min (ANR) or above. | |